Datasheet is currently unavailable. Try again or CONTACT US
Datasheet

WM3000 Purified Genomic DNA

WM3000-02-1000
10 µg
Liquid
Human
$2,469.00 /Per Item
Shipping info:

$50.00 to US & $70.00 to Canada for most products. Final costs are calculated at checkout.

Product Details

WM3000 Purified Genomic DNA - WM3000-02-1000
Melanoma, patient derived tumor, tumor models, skin cancer, xenograft
Human

Target Details

Genomic DNA was purified from cells using genomic DNA preparaton kit according to manufacturers instruction. DNA was diluted to 200 ng/µL in TE buffer (0.01 M Tris Chloride, 0.001 M EDTA, pH 7.6). Concentration was determined at A260 using nanodrop ND-1000.

Application Details

Purified Genomic DNA is suitable for a number of molecular biology applications including but not limited to preparation of genomic libraries, PCR templates, DNA sequencing, DNA fingerprinting, and mutation analysis.

Cell Line Data

Human Melanoma
DNA
WT
WT
Q61R
WT

Formulation

200 ng / µl by UV absorbance at 260 nm
0.01 M Tris Chloride, 0.001 M EDTA, pH 7.6
None
None

Shipping & Handling

Dry Ice
Store vial at -20° C or COLDER. For extended storage, aliquot contents to minimize freeze/thaw cycles.
Expiration date is six (6) months from date of receipt.
DNA was prepared from cell line WM3000. WM3000 is a metastatic human melanoma cell line that displays a melanocytic morphology. This cell line contains a Q61R mutation at position 61 in the N-RAS gene. The Q61R is the most common NRAS mutation found in melanoma that is thought to occur due to UV and radiation exposure. This mutation leads to production of a constitutively active N-RAS protein that directs cells to grow and divide constantly. WM3000 cells are from same patient as WM 2032. These cells are expected to produce xenograft tumors when injected into immunocompromised mice.

Invalid lot number

If you need help finding your CoA, contact us

No test method can provide total assurance that the hepatitis B virus, hepatitis C virus, human immunodeficiency virus, or any other infectious agents are absent. Thus, all blood products, including purified proteins derived from human blood sources, should be handled at Biosafety Level 2 as recommended by the CDC\NIH manual entitled Biosafety in Microbiological and Biomedical Laboratories for potentially infectious human serum, blood specimens or proteins derived from same. Source material for the human blood product supplied to your facility has been tested for the detection of HIV antibody, Hepatitis B surface antigen, antibody to Hepatitis C, HIV 1 antigen(s), antibody to HTLV - I/II, and syphilis by FDA guidelines. All units were found to be non-reactive/negative for these tests. All human blood source material is collected in FDA licensed centers and is tested with FDA approved test kits.; Cell Line Limited Use License Required. THIS PRODUCT IS SUBJECT TO AN END-USER LICENSE AGREEMENT (EULA). BY ACCEPTING THIS PRODUCT, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF USE SET FORTH BELOW and SET FORTH IN THE EULA. THIS PRODUCT IS FOR IN VITRO RESEARCH USE ONLY. THERAPEUTIC, DIAGNOSTIC, OR VETERINARY USE IS PROHIBITED. This product may not be resold or transferred by the recipient and may be used only by the recipient, in the recipient’s facility and only for research use and other uses specifically permitted by the EULA. No other commercial use is allowed. “Commercial Use” means any and all uses of this product by recipient or others for monetary or other consideration, including providing services, supplying information or data to unaffiliated third parties, and resale or transfer of this product for any use. Recipient has no right to modify, derivatize, genetically engineer or otherwise create variations of this product or associated cells or cell lines. ROCKLAND AND WISTAR MAKE NO REPRESENTATIONS AND EXTEND NO WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR THAT THE USE OF THE PRODUCTS WILL NOT INFRINGE ANY PATENT, COPYRIGHT, TRADEMARK, OR OTHER PROPRIETARY RIGHTS. The terms set forth herein and in the EULA shall be governed by the laws of the Commonwealth of Pennsylvania, USA. To obtain a COMMERCIAL USE license for this product, please contact Rockland Immunochemicals, Inc. Please contact a technical service representative for more information. All properties listed are typical characteristics and are not specifications. All suggestions and data are offered in good faith but without guarantee as conditions and methods of use of our products are beyond our control. All claims must be made within 30 days following the date of delivery. The prospective user must determine the suitability of our materials before adopting them on a commercial scale. Suggested uses of our products are not recommendations to use our products in violation of any patent or as a license under any patent of Rockland Immunochemicals, Inc. If you require a commercial license to use this material and do not have one, then return this material, unopened to: Rockland Inc., P.O. BOX 5199, Limerick, Pennsylvania, USA.